title: "The server quit without updating PID file (/usr/local/mysql/data/centos7.pid)."
author: "H小阿飞"
date: "2016-07-01T09:14:44Z"
tags: []
categories: ["数据库"]
slug: "the-server-quit-without-updating-pid-file-usr-local-mysql-data-centos7-pid"
draft: false
lastmod: "2016-07-01T09:17:04Z"
id: 2308454
url: "https://tim-fly.iteye.com/blog/2308454"
---

关于此问题，之前搞数据库的时候出现过一次，也不知道当时怎么折腾的，估计也是网上找资料给解决了。郁闷的是，今天启动mysql的时候，又突然出现这个问题，可是我忘记上次怎么解决的了，遂记录一下，方便日后再遇到这情况好解决

我只能说，遇到这个情况，就去less /usr/local/mysql/data/centos7.err中看日志，不难看出，问题日志就是这些：

160701  8:47:55 InnoDB: Initializing buffer pool, size = 128.0M

InnoDB: mmap(137363456 bytes) failed; errno 12

160701  8:47:55 InnoDB: Completed initialization of buffer pool

160701  8:47:55 InnoDB: Fatal error: cannot allocate memory for the buffer pool

160701  8:47:55 \[ERROR] Plugin 'InnoDB' init function returned error.

160701  8:47:55 \[ERROR] Plugin 'InnoDB' registration as a STORAGE ENGINE failed.

160701  8:47:55 \[ERROR] Unknown/unsupported storage engine: InnoDB

160701  8:47:55 \[ERROR] Aborting

 

160701  8:47:55 \[Note] /usr/local/mysql/bin/mysqld: Shutdown complete

 

虽然上面的日志我不是能全部看懂，因为有几个单词我不懂，但是能猜个大概，因为我认识memory这个词啊，是内存的意思，我想，估计就是内存的问题了，遂去vi /etc/mysql.cnf中修改innodb\_buffer\_pool\_size = 64M的值，然后启动就OK了。

 

这边我要说的，也许你报的错跟标题一下，但是进日志一看，或者跟我的并不一样，重要的是如何查找问题，定位问题，而不是盲目的解决。要学会看日志，这个很重要，虽然很重要，但是我在这儿就不说三遍了。

 

最后我还要严重谴责那些网络上copy来copy去的错误文章，都不自己去验证一下，直接copy过来